Cells & Batteries Testing

As per IS 1651

As per IEC: 60896-11

a. Verification of Constructional Requirement

a. Capacity test

b. Marking & Packing

b. Charge retention Test

c. Verification of Dimension

c. Endurance in discharge-Charge Cycle

d. Ah and Watt Hr Efficiency test

d. endurance in over charge

 

e.Test for suitability for floating battery operation

 

f. Short Circuit and internal resistance test

Secondary batteries play an essential role, usually as a source of standby power, in many areas of business and commerce, such as telecom and data centers. To ensure those batteries deliver their full performance when called upon to do so, you must rely on a regular testing regime.


Many dedicated test labs across the country have rendered their testing and development services especially in Delhi & NCR due to increasing demand for portable dc power has risen from improvements in battery. Classic Lab also was fortunate enough and had the opportunity to serve various agencies engaged in the battery testing due to rechargeable batteries appear in all types of products from analytical electronic equipment to power tools and toys.


With the focus on lithium-ion technology, In Classic Testing Lab, batteries are tested for performance and stability under predefined environmental conditions. Classic Lab has over 20 years of experience in this area of testing.


Following test facilities are offered to the customers-
• Temperature and climate change tests
• Vibration and shock tests
• Corrosion and noxious gas tests
• Electromagnetic compatibility tests
• Battery cycling tests


Battery testing as per IS 1651

The scope of this standard specifies the rated Ah capacities, overall dimensions, performance requirements and test of stationary Lead acid cells and batteries using tubular positive plates.


What is the importance of battery testing?

Battery testing is very beneficial to all of us so, before discussion we must know the basics of this. In this contemporary epoch, batteries are very important as they are store house of power backup and are portable. They provide energy when there is no electricity supply and store power for future use. The uses of batteries cannot be counted on fingertips. They are widely used in industries, houses, vehicles, mobiles, offices, Laptops, in medical equipments and many more.

First of all we must know, what battery testing is? It is the procedure to check whether a Battery (EUT equipment under test or sample) conforms to Indian or International battery standards and it give its full performance. Battery testing gives a clear picture of the 3 main parameters, capacity (means its ability to store power), internal resistance (means that ability to deliver current) and self discharge.  For proper function of the battery, the level of the charges must be maintained.

Batteries are very costly to buy and life of UPS batteries is marketed as 9-10 years, but averagely we have to replace the battery after 5 – 6 years of time span. So, the battery testing shows us the clear picture of the battery. The batteries are generally sold out at higher price, if gone through the safety standards and pass through all the testing formalities.  Battery testing provides result of many parameters like, the life of the battery, capacity.

Classic Lab is a NABL accredited Lab to perform Type test, Acceptance test and performance test for Lead acid batteries.  As batteries are the need of an hour in this modern era so, to buy a genuine and safe product is our right. Hence battery testing is essential for our economy and safety.


Usual methods for battery testing:

Battery testing is done to estimate the state of health, cycle life, actual capacity, state of charge of the battery or bank. There are two methods to test battery, invasive and non invasive methods. 


TESTING SERVICES

  • Battery Testing
  • Cable Gland Testing
  • Cable Tray Testing
  • Calibrating a UV intensity Meter
  • Corrosion Testing
  • Electrical Motor Testing
  • Electrical safety Testing for Lighting products
  • Electrical Safety Testing for Medical Devices
  • Electrical Safety Testing of Electromedical Equipment
  • Electrical Testing
  • Electrical Testing for Automotive Components
  • Electronic Testing
  • EMC Testing
  • EMC/EMI Testing
  • Environmental Testing
  • Household Equipment – Consumer Product Testing
  • Household Equipment Testing
  • IEC 60204-1
  • Safety of Machinery Testing
  • IEC 60204-1 Testing
  • IEC 60601 Testing
  • IEC 60884-1 Plugs and Socket-
  • Outlets for Household and Similar Purpose
  • Information Technology Testing
  • IP Testing
  • LED Driver and
  • Lamp Control Gear Testing
  • LED OT Light Testing
  • LM 80 Testing
  • LM-79 Testing
  • Luminaries/LED Product Testing
    Machinery
  • Equipment Testing
  • Mechanical testing
  • Medical Bed Testing
  • Microwave Oven Testing
  • Mixer Grinder Testing
  • Mixing and Stirring Laboratory
  • Equipment Testing as per Standard
  • IEC 61010-2-051
  • Nerve and Muscle Stimulator Testing as per IEC 60601-2-10
  • Packaging Testing for Transportation of Lithium ion Batteries
  • Patient Monitor testing IS 13450
  • PART 2 SEC 49/
  • IEC 80601-2-49/ISO 80601-2-49
  • Photometry Testing
  • Photovoltatc (PV) Modules Testing
  • Refrigerator Testing
  • RoHS Testing
  • Room Heater Testing
  • Safety Testing for Face
  • Shield/Mask/Respirators Mask
  • Sensor Testing as per Standard IEC 60751
  • Software Testing
  • Solar Fence Energizer Testing
  • Testing of Commercial Refrigerators & Freezers 60035-2-24
  • Testing of Automatic Sanitizer Dispenser/Soap Dispenser as per IEC 60335-1
  • Testing of Electric Food Mixers & Grinders IS 4250
  • Testing of Vertical Road signs – EN 12966 – Variable Message Signs
  • Usability Testing of Medical Devices – IEC 62366
  • UV Testing: Testing of UV light Bulbs
  • Ventilator testing Lab as per: ISO 80601-2-12:2020
  • Vibration Testing

S. No

Products

IS /IEC Standards

1

Secondary cells and batteries containing alkaline or other non-acid electrolytes : Safety requirements for Portable Sealed secondary cells, and batteries made from them,  for use in portable application

IS 16046/ IEC 62133

2

Secondary Cells and Batteries containing alkaline or other non-acid electrolytes – Secondary lithium cells  and batteries  for portable applications

IS 16047/IEC 61960

3

Secondary Cells and batteries for photovoltaic energy systems (PVES)- General requirements and methods of test

IEC 61427

4

Stationary Valve Regulated Lead Acid Batteries- Specification

IS  15549

5

Stationary Lead-Acid Batteries (With Tubular Positive Plates) in Monobloc Container- Specification

IS 13369

6

Secondary Cells and batteries for solar photovoltaic application- General requirements and methods of test

IS 16270

Address : Classic Chowk, Sector-65, Noida-201307 (U.P)

Mob : +91-9717699751, Email  Id : classiclab@gmail.com

For Calibraion Services Click Here : www.classiclab.in